Beam trip diagnostic system at SSRF

HOU Hongtao1,2,3 ZHAO Shenjie1,3 LUO Chen1,3 ZHAO Yubin1,3 ZHANG Zhigang1,3 FENG Ziqiang1,3 MAO Dongqing1,3 LIU Jianfei1,3,*   

  1. 1Shanghai Institute of Applied Physics, CAS, Shanghai 201800, China 2Graduate University of Chinese Academy of Sciences, Beijing 100049, China 3Shanghai KEY Laboratory of Cryogenics & Superconducting RF Technology, Shanghai 201800, China
PDF ShareIt Export Citation
HOU Hongtao, ZHAO Shenjie, LUO Chen, ZHAO Yubin. Beam trip diagnostic system at SSRF.Nuclear Science and Techniques, 2009, 20(5): 261-264     doi: 10.13538/j.1001-8042/nst.20.261-264

Abstract:

In this paper we report the design and realization of beam trip diagnostic system at Shanghai Synchrotron Radiation Facility (SSRF). The system can find out the first fault signal in the key operation signals related to the RF system by analyzing the time sequence, also it can decide which trips occurs first among the three superconducting RF stations. All the states of monitored signals in a time period ahead and behind beam trip are recorded. The results are compared with those from other diagnostic tools at SSRF. The work is of help in improving reliability of the superconducting RF system and stability of the storage ring operation.

Key words: Trip, Shanghai Synchrotron Radiation Facility (SSRF), Radiation frequency (RF)