Abstract: Superconducting TF and PF coils have been measured in SULTAN test facility. Segregated copper strands are included in four NbTi CICC and this is a technical innovation. Two AC losses measurement methods, calorimetric and electromagnetic methods, have been used in the experiments, and a broad frequency range (from 0.05 Hz to 6 Hz) is covered in sample test. The purpose of this experiment was to investigate AC losses of TF and PF CICC conductor including segregated copper and to check the design of PF and TF CICC coated with different resistive barriers (Pb–30Sn-2Sb and Ni plating on NbTi strands).

Key words: Cable-in-conduit conductor, Coupling loss time constant, Sn and Ni plated conductor, Contact resistance