Nuclear Science and Techniques

《核技术》(英文版) ISSN 1001-8042 CN 31-1559/TL     2019 Impact factor 1.556

Nuclear Science and Techniques ›› 2016, Vol. 27 ›› Issue (2): 42 doi: 10.1007/s41365-016-0042-5

• NUCLEAR ELECTRONICS AND INSTRUMENTATION • Previous Articles     Next Articles

Modeling operation amplifier based on VHDL-AMS for TID effect

Jin-hui Liu, Quan Wang , Ying Zhang, Gang Liu, Bo Wan   

  1. Research Institute of Computer Peripherals, Xidian University, Xi’an, Shaanxi Province, China
  • Contact: Quan Wang E-mail:qwang@xidian.edu.cn
PDF ShareIt Export Citation
Jin-hui Liu, Quan Wang, Ying Zhang, Gang Liu, Bo Wan. Modeling operation amplifier based on VHDL-AMS for TID effect.Nuclear Science and Techniques, 2016, 27(2): 42     doi: 10.1007/s41365-016-0042-5
Citations
Altmetrics

Abstract:

A model of the operational amplifier based on VHDL-AMS is proposed. According to needs of simulating the total ionizing dose (TID) radiation effect, parameters of operational amplifier are taken into account when the performance is specified. The operational amplifier model used for the TID radiation effect simulation is completed after verifying each modeled parameter. And a parameter for describing the external environment is introduced to make the model combined with TID. Finally, an example is used to illustrate the TID effect on the operational amplifier of MC14573, proving the validity of the model.

Key words: Behavioral modeling, Operational amplifier, Total ionizing dose (TID), Radiation effects, VHDL-AMS