Design of a mechanical sealing structure for the synchrotron radiation water-cooled crystal

Li SONG1,2,Yichen FAN1,2,Limin JIN1,2(),Zhongmin XU1,2()   

  1. 1. Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China
    2. Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
  • Received:2018-09-05 Revised:2019-02-28 Online:2019-05-10 Published:2019-05-16
  • Contact: Limin JIN,Zhongmin XU E-mail:lmjin@sinap.ac.cn XU Zhongmin;lmjin@sinap.ac.cn;lmjin@sinap.ac.cn XU Zhongmin;xuzhongmin@sinap.ac.cn
  • About author:SONG Li, female, born in 1984, graduated from Zhejiang University with a master’s degree in 2009, senior engineer, focusing on synchrotron radiation optics & technology|SONG Li, female, born in 1984, graduated from Zhejiang University with a master’s degree in 2009, senior engineer, focusing on synchrotron radiation optics & technology|JIN Limin, E-mail: lmjin@sinap.ac.cn XU Zhongmin, E-mail: xuzhongmin@sinap.ac.cn|JIN Limin, E-mail: lmjin@sinap.ac.cn XU Zhongmin, E-mail: xuzhongmin@sinap.ac.cn
  • Supported by:
    Supported by National Natural Science Foundation of China(No.11805262, No.U1832172)

Abstract: Background

The water-cooled crystals at Shanghai synchrotron radiation facility (SSRF) are currently vacuum sealed by colloid bonding. In high-energy synchrotron radiation environments, the colloid is prone to failure that will cause the crystal to flake off.

Purpose

This study aims to introduce the recommended sealing method to avoid the above risks.

Methods

Water-cooled crystal sealing structure was applied to mechanical clamping mechanism. Experimental tests were conducted to obtain surface error in meridian direction of crystal caused by mechanical load and rocking curve. In addition, the water pressure resistance test and leak detection test of the mechanically sealed water-cooled crystal were carried out.

Results

The slope error of the crystal caused by mechanical load is approximately 3.55 μrad (root mean square) which satisfies the performance requirements. Rocking curve test shows that the value of full width at half maximum (FWHM) of the water-cooled crystal of the mechanical sealing structure is 11.86″ which is nearly the same as the FWHM value of 12.24″ of the water-cooled crystal under the original bonding mode, and the difference is about 3%. The results of water pressure resistance and leak detection tests show that the sealing performance of the crystal assembly structure is pretty good.

Conclusions

The water-cooled crystal sealed by mechanical clamping can meet the performance requirements, and it can effectively avoid the occurrence of peeling off event of crystal during work, and provided the necessary guarantee for the stable operation of beam lines at SSRF.Key words Synchrotron radiation, Water-cooled crystal, Mechanical sealing, Slope error, Rocking curve