1 Ewert U, Bavendiek K, Robbins J, et al. New compensation principles for enhanced image quality in industrial radiology with digital detector arrays[J]. Materials Evaluation, 2010, 68(2):163-1682 梁丽红, 路宏年. X射线数字成像系统传递函数模型[J].北京航空航天大学学报, 2005, 31(9):1018-1021 LIANG Lihong, LU Hongnian. Transfer function model on X-ray digital radiography system[J]. Journal of Beijing University of Aeronautics and Astronautics, 2005, 31(9):1018-10213 邵军明, 路宏年, 蔡慧. X射线成像系统点扩展函数理论模型及其实验验证[J]. 光学技术, 2005, 31(1):104-106 SHAO Junming, LU Hongnian, CAI Hui. Research of X-ray imaging system point spread function in theory and experiment[J]. Optical Technique, 2005, 31(1):104-1064 邵军明, 路宏年, 候涛. 射束有效宽度与成像系统MTF关系的研究[J]. 光学技术, 2003, 29(2):242-244 SHAO Junming, LU Hongnian, HOU Tao. Research of relation between X-ray beam effective width and MTF of imaging system[J]. Optical Technique, 2003, 29(2):242-2445 Standard guide for radioscopy:ASTM E1000-98(2009)[S]. ASTM International, 2009. DOI: 10.1520/E1000-98R096 Shaw C C, Liu X M, Lemacks M, et al. Optimization of MTF and DQE in magnification radiography-a theoretical analysis[C]. Proceedings of SPIE (International Society for Optical Engineering), 2000, 3977:466-4757 Sakellaris T, Koutalonis M, Spyrou G, et al. A Monte Carlo study of the influence of focal spot size, intensity distribution, breast thickness and magnification on spatial resolution of an a-Se digital mammography system using the generalized MTF[J]. Physica Medica, 2014, 30:286-2958 Chandrasekharan K N, Patil B P, Ghosh J K. Continuous motion radiography:system evaluation using modulation transfer function[J]. Insight, 1995, 37(2):101-1049 袁永腾, 缪文勇, 丁永坤, 等. ICF 流体力学不稳定性实验中调制传递函数的测量[J]. 强激光与粒子束, 2009, 21(2):245-248 YUAN Yongteng, MIAO Wenyong, DING Yongkun, et al. Mdulation transfer function measurement in ICF hydrodynamic instability experiments[J]. High Power Laser and Particle Beams, 2009, 21(2):245-24810 刘海宽, 张建, 王昌元, 等. 用星形测试卡测试屏-片系统MTF的实验探讨与应用[J]. 中国医学物理学杂志, 2006, 23(4):250-252 LIU Haikuan, ZHANG Jian, WANG Changyuan, et al. Testing screen/film system MTF using star testing card[J]. Chinese Journal of Medical Physics, 2006, 23(4):250-25211 Kaftandjian V, Zhu Y M, Roziere G, et al. A comparison of the ball, wire, edge, and bar/space pattern techniques for modulation transfer function measurements of linear X-ray detectors[J]. Journal of X-ray Science and Technology, 1996, 6:205-22112 王雨, 韩松柏, 贺林峰, 等. 中子照相图像分辨率计算方法[J]. 核技术, 2012, 35(4):275-280 WANG Yu, HAN Songbai, HE Linfeng, et al. Calculation methods for neutron radiography spatial resolution[J]. Nuclear Techniques, 2012, 35(4):275-28013 Nickoloff L E, Donnelly E, Eve L, et al. Mammographic resolution:influence of focal spot intensity distribution and geometry[J]. Medical Physics, 1990, 17(3):436-44714 孙朝明, 汤光平, 李强, 等. X射线源焦点尺寸的测试与对比分析[J]. 核技术, 2015, 38(11):110202. DOI:10.11889/j.0253-3219.2015.hjs.38.110202 SUN Chaoming, TANG Guangping, LI Qiang, et al. Comparative analysis and measurement of focus spot for X-ray source[J]. Nuclear Techniques, 2015, 38(11):110202. DOI:10.11889/j.0253-3219.2015.hjs.38.11020215 Standard practice for manufacturing characterization of digital detector arrays:ASTM E2597-14[S]. ASTM International, 2014. DOI:10.1520/E2597_E2597M-1416 Pitcher D C. Quantitative metrics to evaluate image quality for computed radiographic images[D]. Florida:University of Florida, 200417 江孝国, 谭肇, 李泽仁, 等. X光面光源的尺寸对系统线扩展函数的影响[J]. 强激光与粒子束, 2004, 16(3):296-300 JIANG Xiaoguo, TAN Zhao, LI Zeren, et al. Influence of X-ray area-source on LSF in radiography system[J]. High Power Laser and Particle Beams, 2004, 16(3):296-300 |